Blumenthal EZ, Horani A, Sasikumar R, Garudadri C, Udaykumar A, Thomas R.

Ophthalmic Surg Lasers Imaging. 2006 May-Jun;37(3):218-23.
Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel.

ABSTRACT:

BACKGROUND AND OBJECTIVE: To correlate structure and function in eyes with end-stage glaucoma.

PATIENTS AND METHODS: Fifty-six eyes of 48 patients with glaucoma presenting with end-stage glaucoma underwent scanning laser polarimetry (SLP) imaging using a commercially available GDx-variable corneal compensator unit (GDx-VCC; Laser Diagnostics Technologies, Inc., San Diego, CA). End-stage glaucoma was defined by both disc appearance and standard automated perimetry visual field criteria. Standard automated perimetry parameters included: mean deviation, pattern standard deviation, and total deviation plot. GDx parameters included: TSNIT average, superior average, inferior average, TSNIT standard deviation, and nerve fiber indicator.

RESULTS: The visual field mean deviation was -26.75 +/- 3.50 dB. The remaining retinal nerve fiber layer measured in this group of eyes was: TSNIT average, 29.76 +/- 5.81 microm; superior average, 30.76 +/- 6.25 microm; and inferior average, 31.14 +/- 7.20 microm. A low structure-function correlation was found when analyzing separately the superior and inferior hemifields (R2 = 0.00001, R2 = 0.0016, respectively).

CONCLUSIONS: In eyes with end-stage glaucoma, very thin but existing retinal nerve fiber layer is found on SLP. Such values rarely dropped below 10 to 20 microm. A flattening of the GDx TSNIT pattern was seen, and the correlation between structure and function was not evident.

Article as Full-Text PDF

Figure from this article:

Related Posts

Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty
Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew...
List of Publications- by Prof. Eytan Blumenthal
ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos...
Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must?
Blumenthal EZ. Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8. Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjusting the slit-lamp eyepiece rings is perceived by some...
On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting--What Is There To Lose?
Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the...
Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure
Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem,...