Glaucoma & Cataract, Prof. Eytan Blumenthal

List of Publications- by Prof. Blumenthal

Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty

Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: Ocular hypertension is a potentially serious complication after penetrating keratoplasty (PKP). Our objective is to determine the risk factors, incidence, […]

Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty Read More »

List of Publications- by Prof. Eytan Blumenthal

ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos CN. On focusing the slit-lamp. Part I: An inaccurate ocular setting, what is there to lose.  Survey of Ophthalmology 1998;42(4):351-354. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos CN. On focusing the

List of Publications- by Prof. Eytan Blumenthal Read More »

Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must?

Blumenthal EZ. Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8. Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjusting the slit-lamp eyepiece rings is perceived by some to be insignificant for achieving adequate focus. Others assume that these rings should be set only to compensate for one’s refractive error. Observations are presented concerning the eyepiece scale setting during

Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must? Read More »

On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting–What Is There To Lose?

Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the slit-lamp oculars compensate for three independent factors: the observer’s refractive error, the observer’s state of accommodation, and any instrument misalignment. An inaccurate setting of these rings will significantly affect the slit-lamp

On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting–What Is There To Lose? Read More »

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure

Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: To report the clinical course of early transient reduction of uncorrected visual acuity (UCVA) after LASIK surgery resulting from steroid-induced elevation of intraocular pressure (IOP).

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure Read More »

On Focusing The Slit-Lamp: Part II. “The Fading-Slit Test” Verifying The Ocular Setting

Blumenthal EZ, Serpetopoulos CN Surv Ophthalmol. 1998 Jan-Feb;42(4):355-7. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT The focusing-rod test is considered the gold standard for determining the correct setting of the slit-lamp ocular rings. This method is, however, somewhat time-consuming, considering the time it often takes to locate a rod every time one switches

On Focusing The Slit-Lamp: Part II. “The Fading-Slit Test” Verifying The Ocular Setting Read More »

The Role Of Preoperative Ultrasonography For Patients With Dense Cataract: A Retrospective Study Of 509 Cases

Anteby II, Blumenthal EZ, Zamir E, Waindim P. Ophthalmic Surg Lasers. 1998 Feb;29(2):114-8. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: BACKGROUND AND OBJECTIVE: Ocular ultrasonography is widely used for the evaluation of eyes with opaque ocular media. Although preoperative ultrasonography of the globe has been recommended for patients with dense cataracts, the value

The Role Of Preoperative Ultrasonography For Patients With Dense Cataract: A Retrospective Study Of 509 Cases Read More »

Aligning The Goldmann Tonometer Tip By Means Of The “Precontact Whitish Rings”

Blumenthal EZ. Surv Ophthalmol. 1999 Sep-Oct;44(2):171-2. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: A set of whitish rings observed before contact is made during Goldmann-type applanation tonometry can help simplify and speed the examination. The orientation and size of the rings are useful both in aligning the tonometer and in estimating the distance

Aligning The Goldmann Tonometer Tip By Means Of The “Precontact Whitish Rings” Read More »

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma

Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN. Invest Ophthalmol Vis Sci. 2000 Jun;41(7):1783-90. Department of Ophthalmology, University of California at San Diego, La Jolla 92093-0946, USA. ABSTRACT: PURPOSE: To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma Read More »

Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples

Pe’er J, Blumenthal EZ, Frenkel S. Br J Ophthalmol. 2007 May;91(5):660-2. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, PO Box 12000, 91120 Jerusalem, Israel. peer@md.huji.ac.il ABSTRACT: AIM: To obtain iris biopsy samples of sufficient quality and quantity for histopathological analysis using a novel punch biopsy technique. METHODS: Two patients underwent iris tumour biopsy at an

Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples Read More »