Bowd C, Zangwill LM, Blumenthal EZ, Vasile C, Boehm AG, Gokhale PA, Mohammadi K, Amini P, Sankary TM, Weinreb RN.

J Opt Soc Am A Opt Image Sci Vis. 2002 Jan;19(1):197-207.
Glaucoma Center, Department of Ophthalmology, University of California, San Diego, La Jolla 92093-0946, USA. cbowd@eyecenter.ucsd.edu

ABSTRACT:

We cross-sectionally examined the relationship between age, optic disc area, refraction, and gender and optic disc topography and retinal nerve fiber layer (RNFL) measurements, using optical imaging techniques. One eye from each of 155 Caucasian subjects (age range 23.0-80.8 y) without ocular pathology was included. Measurements were obtained by using the Heidelberg Retina Tomography (HRT), the GDx Nerve Fiber Analyzer, and the Optical Coherence Tomograph (OCT). The effects of age were small (R2 < 17%) and were limited to specific HRT, GDx, and OCT parameters. Disc area was significantly associated with most HRT parameters and isolated GDx and OCT parameters. Refraction and gender were not significantly associated with any optic disc or RNFL parameters. Although effects of age on the optic disc and RNFL are small, they should be considered in monitoring ocular disease. Optic disc area should be considered when cross-sectionally evaluating disc topography and, to a lesser extent, RNFL thickness.
Article as Full-Text PDF

Figures from this article:

Related Posts

Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty
Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew...
List of Publications- by Prof. Eytan Blumenthal
ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos...
Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must?
Blumenthal EZ. Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8. Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjusting the slit-lamp eyepiece rings is perceived by some...
On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting--What Is There To Lose?
Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the...
Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure
Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem,...